There are some Optyma™ Compact Line units which are used with R22 for LBP applications. According to legislation the usage of R22 is limited or even forbidden, but for some markets and regions R22 is the main refrigerant.
1. Optyma™ Compact Line, R22/LBP B20
Receiver, filter drier, high/low-pressure switch (HP - cartridge, LP - KP1), crankcase heater, shut-off valves Version B20 is a basic model for medium/large cooling capacities. It comes with hermetic or semi-hermetic reciprocating compressors, fin-and-tube condenser, receiver, filter drier, high/low-pressure switch (HP - cartridge, LP - KP1), crankcase heater and shut-off valves. This version is produced in Brazil.
2. Optyma™ Compact Line, R22/LBP B49
Receiver, filter drier, sight glass, high/low-pressure switch (HP - cartridge, LP - KP1), crankcase heater, shut-off valves, electrical box, oil separator, suction line accumulator. Version B49 is a model for medium/large cooling capacities. It comes with hermetic or semi-hermetic reciprocating compressors, fin-and-tube condenser, receiver, filter drier, high/low-pressure switch (HP - cartridge, LP - KP1), crankcase heater and shut-off valves, electrical box (thermal overload relay, compressor contactor, sequence phase relay, control fuse), oil separator and suction line accumulator. This version is produced in Brazil.
Название характеристики | Значение |